[Ups] SignallingType=Smart PortName=COM2 AutoUpsRebootEnabled=Yes [EventLogging] EventLogEnabled=Yes EventLogName=C:\PWRCHUTE\pwrchute.log EventLogMaxSize=50000 [ErrorLogging] ErrorLogEnabled=Yes ErrorLogName=C:\PWRCHUTE\pwrchute.err ErrorLogMaxSize=50000 [Messaging] MessageDelay=10 MessageInterval=30 [Shutdown] AdminShutdownDelay=900 DailyShutdownEnabled=No DailyShutdownTime=6:00 PM DailyWakeupTime=7:00 AM WeeklyShutdownEnabled=No WeeklyShutdownDay=Friday WeeklyShutdownTime=6:00 PM WeeklyWakeUpDay=Monday WeeklyWakeUpTime=7:00 AM [Server] HostName=Local Host [UserInterface] TemperatureUnits=Fahrenheit SoundEffects=No [EventText] 100000=*** PowerChute Pro Version 1.0 Started *** 100100=*** PowerChute Pro Stopped *** 100200=Communication established 100300=Normal power restored: UPS on line 100400=UPS self-test passed 100402=User initiated UPS self-test passed 100403=Self-test at UPS passed 100500=Administrative shutdown started 100501=Administrative shutdown: User initiated 100502=Administrative shutdown: Weekly shutdown 100503=Administrative shutdown: Daily shutdown 100600=Shutdown cancelled 100601=User initiated shutdown cancelled 100602=Weekly administrative shutdown cancelled 100603=Daily administrative shutdown cancelled 100700=UPS returned from low battery condition 100701=UPS returned from low battery condition: #BATTERY_CAPACITY# 100900=UPS batteries no longer need replacing 101300=UPS overload condition solved 101600=Shutdown started 101601=User initiated shutdown started 101602=Weekly administrative shutdown started 101603=Daily administrative shutdown started 200000=UPS on battery 200001=UPS on battery: High input line voltage #MAX_VOLTAGE# V 200002=UPS on battery: Brownout #MIN_VOLTAGE# V 200003=UPS on battery: Blackout #MIN_VOLTAGE# V 200004=UPS on battery: Small momentary sag #MIN_VOLTAGE# V 200006=UPS on battery: Deep momentary sag #MIN_VOLTAGE# V 200005=UPS on battery: Small momentary spike #MAX_VOLTAGE# V 200007=UPS on battery: Large momentary spike #MAX_VOLTAGE# V 200008=UPS on battery: Simulated power failure 200100=System shutdown 200101=System shutdown: #INITIATOR# initiated 200200=UPS enabling Smart Boost 200300=Low battery condition 200301=Low battery condition: #BATTERY_CAPACITY# 300000=Unable to communicate with UPS 300100=UPS output overload 300200=UPS self-test failed 300203=User initiated self-test failed: Bad battery 300204=User initiated self-test failed: Invalid test 300205=Self-test at UPS failed: Bad battery 300206=Self-test at UPS failed: Invalid test 300300=UPS battery is discharged 300301=UPS battery is discharged: #BATTERY_CAPACITY# 300400=Communication lost while on battery 301600=UPS battery needs replacing [PopupText] 1003=Normal utility power at #HOSTNAME# has been restored. 1006=Shutdown of #HOSTNAME# has been cancelled. 1007=UPS batteries at #HOSTNAME# are no longer discharged. 1016=Shutdown process started. 2000=#HOSTNAME# is running on battery power. 2001=#HOSTNAME# has been shutdown. 2003=Low battery power at #HOSTNAME#. 3000=#HOSTNAME# has lost communications with the UPS. 3003=UPS batteries at #HOSTNAME# are discharged. [FlexEventNames] 1000=PowerChute Started 1001=PowerChute Stopped 1002=Communication Established 1003=Power Restored 1004=UPS Self-Test Passed 1005=Administrative Shutdown 1006=Shutdown Cancelled 1007=UPS Return From Low Battery 1009=Battery No Longer Needs Replacing 1012=UPS Returned From Abnormal Condition 1013=UPS Overload Condition Solved 1016=Start Shutdown Process 2000=UPS On Battery 2001=System Shutdown 2002=UPS Enabling Smart Boost 2003=Low Battery Condition 3000=Unable To Communicate With UPS 3001=UPS Output Overload 3002=UPS Self-Test Failed 3003=UPS Battery Is Discharged 3004=Communication lost while on battery 3012=UPS In Abnormal Condition [LineFail] NotifyDelay=5 NotifyInterval=30 NotifyRepeat=Yes ShutdownDelay=300 Actions=LUS [CommunicationLostOnBattery] ShutdownDelay=0